Morgan Burley Below is a breakdown of how to wire different Intermatic timer models. Not sure if you still answer these but I have a weird one for you. Did I wire it incorrectly or did I just get a bad timer? If I have to tell you which terminals to measure, you shouldnt be doing this! And when switched on, power to the load terminals? make sure it hasnt tripped and is switched on. I currently manually turn it on and off. Clock not turning or making any sound. To do this, pull the yellow-faced time dial (clockface) toward you. In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Paul, it could be that you got a 50hz motor, instead of a 60hz? Terminal A (farthest to the left side) is not connected to anything. I have to reset the time every day. They may be fused together, or could be a lizard stuck in there, or some other foreign object or insects. And there you have it, the quick and easy ways to troubleshoot common Intermatic pool timer problems. The green tripper trips the mechanism closer to the center of the dial and the gold tripper trips the mechanism towards the outer edge of the dial. Rich. Could be small bugs, or dirt, or both causing the problem. Hi, To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. With power off, you could also check the tightness of the on/off switch, it may be missing the tension spring also, check that its there. You could be missing the timer pins, you could have a bad timer, you could have no power to the timer or maybe even the timer is set wrong and it really is working but your not seeing it. For additional tripper pairs on CLOCK-DIALorder 156T1978A. In this post, we discuss a few quick and easy ways to troubleshoot your pumps Intermatic timer clock problems. Wont work manually or by timer function. It could also be loose wires, either on the time clock terminal board, or on the timer motor. Filter pump is ON at all timer Timer contacts welded Replace timer 5 . For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. Intermatic timers are common among pool owners and typically last a long time, but they also can come with problems and may need to be fixed. DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Go for it, a little maintenance expense. I have a white, red, and black wire coming from the power source. If your pool pump timer isn't working, it's likely because of these explanations: Broken timer motor Power outage Circuit breaker problems Loose timer tags Disconnected wires Incorrect time of day Broken internal timer In this article, I'll discuss several reasons your pump's timer won't work. Or the switch can suffer wear over many years, and might not make solid contact. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Most Intermatic timer parts can be renewed but sometimes you need to replace the whole mechanism. My pool timer is in the off position and it is still running. Is it possible to do this by loosening the timer screw a bit? I have noticed that the gears turn when the pool pump is on but they do not when the pump is off, which surely is the reason why it is losing time. Just some ideas. Check the motor, and be sure the label is not printed 50 hz. With this model can I control both of these motors with two different on and off times. First, verify the power is turned off at the breaker panel. But first, pull the mechanism from the box by releasing the tab at the top (be sure breaker is turned off, first), and inspect the gears and copper tabs on the back, to look for something clogging up the works, insects, lizards, sand, etc. It is not warped in any way. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. There are many reasons why your pool timer may not be working. Only perform this step if you are qualified. "headline": "Intermatic Pool Timer Troubleshooting",
You need that 8 hr run in just the summer . This div height required for enabling the sticky sidebar. All Rights Reserved. Sometimes those are looped back to the control box. Jul 20, 2021. Take a good look at the position of the pins and write down the locations. Hi Matthew T104 can only turn one pump on and off. There are many reasons why your pool timer may not be working. It was always fine before. Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. I made sure the trippers were fully inserted and tight. Recently i just notice my T104R timer a bit noisier than usual. "height": "219",
I notice my pool pump was not on so I went and I hear timer running but no juice to the pool filter. View more property details, sales history and Zestimate data on Zillow. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Slide it around the pool timer dial to the correct start time and re-tighten it. That way I could schedule the pump once again. I manually turn it on timer is running, it will trip pump OFF. My intermatic timer is about two years old as well. First, secure the green ground wire to the green ground screw, then connect the other two wires to terminals #1 and #3. Electricity is dangerous and can kill you if you dont know what youre doing. 1. GFCI breakers trip at a very low threshold, doesnt take much. For Sale: 2 beds, 2 baths 1152 sq. So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. Or other advice or explanation. Theres really only 3 causes as to why your pump wont turn on/off. You can also apply some of the troubleshooting steps to other brand timers. Line is incoming, Load goes to the pump. 110V or 220V? It just seems to have a weak start?? 2,767 Sq. Like # 8 09-16-07, 03:09 PM nap New Member Join Date: May 2006 Location: north Posts: 4,162 Pool Timer Not Turning ON or OFF!! Shut off the breaker and check that the wires are tight on the terminals, and that the white wires are connected well on the motor (depress the tab at the top to inspect behind the time clock). Followed all directions and even watched YouTube troubleshooting videos. Ill do the same. screwfindinganame on June 18, 2013 at 11:36 pm Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. I would check that the motor says 60 hz on it and they did not send you a 50 hz by mistake. Any advice on how to fix. Intermatic timers can typically be fixed by checking theres power to the timer, resetting the time, renewing the ON/OFF trippers and renewing the gears or timer motor. If unsure, the White (Neutral) wire connects to the neutral buss bar in the breaker panel, and the Black (Line) wire would connect to the circuit breaker. Pop-in a new timer mechanism, and replace the wires to the previous configuration. The trippers push on a tab on the on/off switch. Hi Chad, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. In most cases like this, replacing the trippers is the solution. "datePublished": "1/10/2020",
I went to the control panel and saw that the timer needle stopped just after the start pointer. Tracing the power it goes from breaker to control panel, and then to the time clock, then to the pump. If its loose, grab a screwdriver and tighten it up. How can I fix this? Also, once it reaches the tripper, the gears in the window no longer move. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. "height": "219",
"wordCount": "1259",
Or is there anything else I can check? Proceed to step 4 to check the timer itself. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. The trippers will "trip" the analog clock to turn on and off automatically at the set times. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Align the bar with the current time and push it back into place. Its best to just write down the spots each timer is in, but remember that its a 24 hours cycle so you will need to come back within 24 hours to see if the pins moved. Sometimes old power wires split or short-out. Then after a bit, the pump restarts. 3 Baths. I replaced the pump and still nothing is moving. If the trippers are loose, then they could slip and cause issues with the pump turning on/off at the correct times. Also be sure that the front dial is engaged with the gear located behind the dial. More. Report B BadOleRoss 0 LifeTime Supporter Apr 30, 2011 393 Lynchburg VA Aug 21, 2012 #8 If it doesnt, there could be an issue with the clock face or gears. Eldon, the breaker should not be bad, but the timeclock may be wired incorrectly. But eventually, like all equipment, intermatic clocks wear out and need to be replaced or repaired. If not, the motor may be failing. The screw in the center point timer occasionally comes loose due to vibrations from the pump and filter. If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. They are little ants that just came. To reset the time clock to the correct time, grasp the outer edges of the large yellow dial, and pull gently outward. "width": "611",
Assuming the wiring is all correct. Home / Pool Repairs / Equipment Repairs / Intermatic Pool Timer Troubleshooting. I have a T104. Not two OFF trippers? Have you any suggestions at to why I am experiencing this problem? For extra safety, shut-off the Pool breaker on the main home panel too. This is the first step to confirm if there is power or not. Hello. I cant seem to find the exact replacement for this timer on the web and wanted to ask if you knew which intermatic pool timer model would match the one I have. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. The problem lies where the power dies, youve probably heard that before. It has 4 screws below the dial labeled from left to right: LINE 1, LINE 2, LOAD 1, LOAD 2. "name": "Davy Merino",
The 2,810 sq. Is there a control board, PCB in the panel that could have problems? I have an Intermatic t104. If soft, it may not be fully engaging the switch, which is (sort of) visible next to the tab. That will do it. Ive got a weak pump battery so every time the mechanism shuts off it looses time. Problems with Intermatic timers are caused by defective trippers, incorrect wiring, tripped circuit breakers, a faulty time clock motor and incorrectly set power terminals. Hi, then the power for the clock must be from the switch, and not from the breaker? by Intermatic Technical Support | Jul 25, 2022 Helpful? You will feel the wheel pull out about an 1/8 of an inch and then you will be able to rotate the timer wheel. My timer works good it turns on and off when I set the time. Be sure they are intact and are connected firmly on both ends, to the front terminals and to the motor on the reverse. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Any ideas why its doing that? Deep down, I figured it was something I did wrong and it was. Tighten down all brass screws securely, to hold all wires firmly in place. My pool pump timer is not working properly. Phil. The pointer should point straight down, and you pull out on the dial, to set the correct time, aligning the current time with the pointer. Replace the plastic insulator cover, turn on the power, and observe the visual motor check. Im ready to send my back for a replacement. Is it keeping time normally? Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. Test the voltage coming in, it may be incorrect, or out of range (more than 10% above 110v or 220V). Same goes for slipping timer dogs! Still no luck. Does the tripper work on other areas of the clock, like near the off tripper? I unscrewed the clip and put it back on and its still doing the same thing. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears, or the timer motor has burned out. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. Hi Chinh, if the clock gears are not moving, check the two small white wires going to the motor, on the reverse side of the timer mechanism. Does it need lubricant or something? I have heard that perhaps a run of mis-marked motors went out and you may have a 50 Hz actually. If all looks well, and the gears are still not turning, you may need to replace the mechanism. Hello, I notice today that my pump wasnt running so I opened the pool breaker panel where the timer is and noticed the breaker was tripped. If the pump comes on, you definitely have power to the timer. It also provides a selectable voltage switch that enables you to choose between 120 and 240V, depending on what voltage you use and also has a battery backup option. Ask Your Own Pool and Spa Question During this the pump cannot be manually switched on. The pool pump can run for 16 hours every day, which means not only will you save electricity, but you also will recover the cost of the timer within 2 years.